Chapter 2 Firmware Commands 47
Response: <SOH>0<CR>
After the controller is in Format Hexadecimal mode, touching the
screen causes the controller to return a response in following format:
<HDR>Xxx,Yyy<CR>
where:
<HDR> = Start-of-header (Hex 01). If you send a Mode Status
command after a Format Hexadecimal command, this first
byte becomes a status byte. The status byte defines
whether the X, Y coordinates are generated from a
touchdown, a touch continuation (when the finger is
resting on the screen), or a touch liftoff. For more
details, refer to the Mode Status command later in this
chapter.
X
xx = X (horizontal) coordinate data. Total of 3 bytes.
, = ASCII comma that separates the X and Y coordinate
data.
Yyy = Y (vertical) coordinate data. Total of 3 bytes.
<CR> = Terminator (Hex 0D).